The extremely high danger zone less than six feet from the roof s edge requires one of the following.
Low slope roof fall protection requirements.
Using safety monitors on low slope roofs.
Except as otherwise provided in paragraph b of this section each employee engaged in roofing activities on low slope roofs with unprotected sides and edges 6 feet 1 8 m or more above lower levels shall be protected from falling by guardrail systems safety net systems personal fall arrest systems or a combination of warning line system and guardrail system warning line system and safety net system or warning line system and personal fall arrest system or warning line system and.
Osha has designated three work zones on low slope roofs with unprotected edges that are four feet or more above a lower level.
A safety monitor is a competent person responsible for recognizing and warning employees they are in danger of falling.
Personal fall arrest system or personal fall restraint system.
The use of a fall protection system is not required for a repair pit service pit or assembly pit that is less than 10 feet 3 m deep provided the employer.
In a few very specific situations low slope roof work some leading edge work precast concrete erection and residential construction.
When engaged in roofing work on a low slope roof that has one or more unprotected side or edge 6 feet or more above lower levels workers must be protected from falling by.
Final paragraph b 13 is a new provision that establishes fall protection requirements when employees perform work on low slope roofs.
A worker may enter or exit an aerial lift at heights above 6 feet provided that fall protection such as guardrails or a fall arrest system is used while the worker moves between the lift and the working surface.
The monitor counts as part of the fall protection solution on low slope roofs.
One that caught my eye was the new requirements for our maintenance personnel who may be doing work on low sloped roofs defined as a roof having a slope less than or equal to 4 in 12 vertical to horizontal.
1910 28 b 8 ii.
Although not all fall protection is created equal and there is a hierarchy of fall protection there are requirements that must be adhered to for low sloped roofs depending on the distance from the roof or leading edge.
See 1926 501 b 2 12 and 13 because of feasibility limitations the standard permits the use of a warning line in combination with other measures instead of conventional fall protection guardrail systems personal fall arrest systems or safety net systems to keep employees away from an edge.
6 feet to less than 15 feet from leading edge acceptable forms of fall protection are.
The following are fall protection options on low slope roofs.
1910 28 b 8 i limits access within 6 feet 1 8 m of the edge of the pit to authorized employees trained in accordance with 1910 30.
In particular 1926 501 b 1 requires fall protection at 6 feet above a lower level.
Roof fall protection standards in regards specifically to roof fall protection the 1910 standard specifies for low slope roofs that when work is performed less than 6 feet 1 6 m from the roof edge the employer must ensure each employee is protected from falling by a guardrail system safety net system travel restraint system or personal fall arrest system.